Module sep2_common::packages::der

source ·
Available on crate feature der only.

Structs

  • The active (real) power P (in W) is the product of root-mean-square (RMS) voltage, RMS current, and cos(theta) where theta is the phase angle of current relative to voltage. It is the primary measure of the rate of flow of energy.
  • Available electric charge
  • The apparent power S (in VA) is the product of root mean square (RMS) voltage and RMS current.
  • DER ConnectStatus value (bitmap):
  • Average flow of charge through a conductor.
  • Data point values for defining a curve or schedule
  • Distributed Energy Resource (DER) time/event-based control.
  • Distributed Energy Resource (DER) control values.
  • Control modes supported by the DER. Bit positions SHALL be defined as follows:
  • Abstract type for specifying a fixed-point value without a given unit of measure.
  • Specifies a signed setpoint for reactive power.
  • Type for Frequency-Droop (Frequency-Watt) operation.
  • DER InverterStatus value: 0 - N/A 1 - off 2 - sleeping (auto-shutdown) or DER is at low output power/voltage 3 - starting up or ON but not producing power 4 - tracking MPPT power point 5 - forced power reduction/derating 6 - shutting down 7 - one or more faults exist 8 - standby (service on unit) - DER may be at high output voltage/power 9 - test mode 10 - as defined in manufacturer status All other values reserved.
  • DER LocalControlModeStatus/value: 0 – local control 1 – remote control All other values reserved.
  • DER ManufacturerStatus/value: String data type
  • DER OperationalModeStatus value: 0 - Not applicable / Unknown 1 - Off 2 - Operational mode 3 - Test mode All other values reserved.
  • Specifies a setpoint for Displacement Power Factor, the ratio between apparent and active powers at the fundamental frequency (e.g. 60 Hz).
  • Specifies a setpoint for Displacement Power Factor, the ratio between apparent and active powers at the fundamental frequency (e.g. 60 Hz) and includes an excitation flag.
  • The reactive power Q (in var) is the product of root mean square (RMS) voltage, RMS current, and sin(theta) where theta is the phase angle of current relative to voltage.
  • Reactive susceptance
  • DER StateOfChargeStatus value: Percent data type
  • DER StorageModeStatus value: 0 – storage charging 1 – storage discharging 2 – storage holding All other values reserved.
  • Abstract type for specifying an unsigned fixed-point value without a given unit of measure.
  • Average electric potential difference between two points.
  • Active (real) energy

Enums