Module sep2_common::packages::der
source · Available on crate feature
der
only.Structs
- The active (real) power P (in W) is the product of root-mean-square (RMS) voltage, RMS current, and cos(theta) where theta is the phase angle of current relative to voltage. It is the primary measure of the rate of flow of energy.
- Available electric charge
- The apparent power S (in VA) is the product of root mean square (RMS) voltage and RMS current.
- DER ConnectStatus value (bitmap):
- Average flow of charge through a conductor.
- Data point values for defining a curve or schedule
- Distributed Energy Resource (DER) time/event-based control.
- Distributed Energy Resource (DER) control values.
- Control modes supported by the DER. Bit positions SHALL be defined as follows:
- Abstract type for specifying a fixed-point value without a given unit of measure.
- Specifies a signed setpoint for reactive power.
- Type for Frequency-Droop (Frequency-Watt) operation.
- DER InverterStatus value: 0 - N/A 1 - off 2 - sleeping (auto-shutdown) or DER is at low output power/voltage 3 - starting up or ON but not producing power 4 - tracking MPPT power point 5 - forced power reduction/derating 6 - shutting down 7 - one or more faults exist 8 - standby (service on unit) - DER may be at high output voltage/power 9 - test mode 10 - as defined in manufacturer status All other values reserved.
- DER LocalControlModeStatus/value: 0 – local control 1 – remote control All other values reserved.
- DER ManufacturerStatus/value: String data type
- DER OperationalModeStatus value: 0 - Not applicable / Unknown 1 - Off 2 - Operational mode 3 - Test mode All other values reserved.
- Specifies a setpoint for Displacement Power Factor, the ratio between apparent and active powers at the fundamental frequency (e.g. 60 Hz).
- Specifies a setpoint for Displacement Power Factor, the ratio between apparent and active powers at the fundamental frequency (e.g. 60 Hz) and includes an excitation flag.
- The reactive power Q (in var) is the product of root mean square (RMS) voltage, RMS current, and sin(theta) where theta is the phase angle of current relative to voltage.
- Reactive susceptance
- DER StateOfChargeStatus value: Percent data type
- DER StorageModeStatus value: 0 – storage charging 1 – storage discharging 2 – storage holding All other values reserved.
- Abstract type for specifying an unsigned fixed-point value without a given unit of measure.
- Average electric potential difference between two points.
- Active (real) energy